- Testing Equipment[8]
- PH Meters[1]
- Gas Analyzers[1]
- Other Analysis Instruments[3]
- Temperature Instruments[10]
- Magnifiers[9]
- Microscopes[8]
- Speed Measuring Instruments[7]
- Other Measuring & Analysing Instruments[7]
- Diagnostic Tools[1]
- Auto Meter[1]
- Multimeters[5]
- Resistance Meters[2]
- Force Measuring Instruments[5]
- Pressure Gauges[6]
- Industrial Metal Detectors[4]
- Moisture Meters[1]
- Other Networking Devices[1]
- Pliers[1]
- Electrical Plugs & Sockets[2]
- Emergency & Clinics Apparatus[6]
- Ultrasonic[2]
- General Assay & Diagnostic Apparatus[3]
- Pill Storage Cases[10]
- Jewelry Tools & Equipment[2]
- Gauges[1]
- Instrument Parts & Accessories[1]
- Projection Screens[10]
- Contact Person : Mr. Chen Joe
- Company Name : Shenzhen Handsome Technology Co., Ltd.
- Tel : 0086-755-25690304, 82357103
- Fax : 0086-755-61351415
- Address : Guangdong,Shenzhen,Rm.# 5E, 5/F, Yongjingyuan, Senwei Building, Xin'an Road, Luohu District,
- Country/Region : China
- Zip : 518002
HPC-602 Portable Smoke opacimeter
HPC-602 Portable Smoke opacimeter
Main Features:
Separated structural design, operation more convenient and more accurate data.
Adopted a triage-type sampling technique, diesel engine acceleration, deceleration, and steady speed can be measured when the smoke;
Linear automatic data processing, can be displayed opacity degrees N, light absorption coefficient K and the corresponding value of filter paper-type smoke SF;
High-brightness digital display;
Use of "air curtain" technology to protect the optical system from contamination;
Automatic detection of room temperature control, anti-condensation can affect the test accuracy;
Automatically attached to the time display; optional speed measurement and oil temperature measurement
Show where the failure of automatic diagnosis unit;
Equipped with built-in printer (or digital RS-232A interface or analog interface);
In line with ISO11614 and GB3847-2005 technical requirements.
Main technical parameters:
Test Scope:
No light transmission N::0~100% (equivalent to smoke value 0 ~ 10FSN)
Light absorption coefficient K:0-16 .06 m-1
RPM:0-9990rpm OIL TEMP: 0-150°C
Indication error of +/- 2% ( measured value)
Stability of automatic zero adjustment, moment drift less than+/-1% / 4H
Repeatability repetition error of+/-1%
Resolution: N:0.1%, K:0.01m-1 ,RPM:10rpm, OIL TEMP:0.1°C
Output mode: digital direct reading, can be attached to the printer to print the smoke concentration ( darkness) maximum value, test time, date. Can interface with computer networking
Measurement of smoke temperature of 70 degrees C ( automatic thermostat ), when the temperature error = + 10%, temperature and error indicator light
Environmental conditions of temperature -5 to 50 DEG C, relative humidity 90%
AC100-240V 50/60Hz 150VA power source power consumption
Dimensions ( including bracket) control portion of the 240mm (L) x 310mm (W) x 170mm (H)
Light path part 130mm (L) x 400mm (W) x 390mm (H)
Weight control section 4kg
Light path part 5kg
HPC-602 Portable Smoke opacimeter